Research
AO Ranking buying guide: reading and comparing pool pumps, sand filters, heat pumps and starting blocks
Using the 35 products currently in the pool-equipment category, this guide compares publisher figures for circulation pumps, sand filters, heat pumps and starting blocks and gives AO Ranking buying views; no source declares a national standard, and sample limits are set out in the text.
Scope
Covers only products already in the library; no prices, sales or market share; no model's standards conformity or event approval is judged.
Sample and how to use this guide
As of 1 November 2026 the site lists 35 pool-equipment products. Brand mix: Emaux 18, AstralPool 10, Ouya 4, Fairland 3. By type: 17 circulation pumps (Emaux 7, AstralPool 10), 13 sand filters (Emaux 11, Ouya 2), 3 heat pumps (Fairland) and 2 starting blocks (Ouya). Sample limits: Emaux and AstralPool make up 80%, the only Chinese brands are Ouya and Fairland, and many AstralPool records hold dimensions only, without power or flow. A dash means the value is not in the library; comparisons show parameter differences only and are not quality rankings. All 35 products received AO Ranking reviews on 1 November 2026; links are at the end.
Circulation pumps: ports and baskets first, then curves
Library pump data centres on ports and baskets: Emaux UPH at 3"/90 mm and 8 L, APS550P / 750P at 4"/DN100 and 13 L, APS1000P / 1500P at 6"/DN150 and 30 L; AstralPool Kivu 56634 / 56635 with 150-6" suction, 125-5" discharge and a 25 L pre-filter. AO Ranking view: port size decides which pipe class the pump joins and basket volume affects how often it is emptied, but the flow-head curves and motor power that actually drive selection are mostly missing from the records, so request them at purchase. The seven AstralPool ARAL PLUS codes carry mounting dimensions only, useful for checking like-for-like swaps in plant-room retrofits. Emaux splits one model into separate codes for 400V 50Hz, 400V 60Hz, 460V 60Hz and others; projects in mainland China should lock the 50Hz code.
5 section citations
Scroll the table to see all fields; original units are retained.
| Model | Ports | Basket / pre-filter | Other library data |
|---|---|---|---|
| Emaux UPH400 / 550 / 700 | 3"/90 mm | 8 L | Three-phase 50 / 60Hz codes |
| Emaux APS550P / 750P | 4"/DN100 | 13 L | Three voltage/frequency codes |
| Emaux APS1000P / 1500P | 6"/DN150 | 30 L | — |
| AstralPool Kivu 56634 / 56635 | 150-6" suction, 125-5" discharge | 25 L | B5 aluminium motor flange |
| AstralPool Kivu 56633 | — | — | 1500 rpm |
| AstralPool ARAL PLUS C-1500 (4 codes) | — | — | Overall length L 1024 / 1053 mm |
| AstralPool ARAL PLUS C-3000 (3 codes) | — | — | Overall length L 857 / 968 / 996 mm |
Sand filters: area, media weight and plant-room limits
Filter area is the most direct comparison. The library's Emaux E range runs from 0.86 m² (E1050) to 3.80 m² (E2200), the dual-stack TH range has 3.02 to 8.16 m² per bed, and the horizontal H3000-10.0 reaches 27.44 m²; Ouya SCD-1200 / SCC-1200 show 1.13 / 1.17 (unit printed as m). Emaux E1200 and Ouya SCD-1200 share 1.13, the only size in the library that compares directly across brands: Ouya gives 51.6 m³/h, about 45.7 m/h filtration rate (AO Ranking calculation), while Emaux gives no flow. AO Ranking view: large tanks are usually limited by the building rather than hydraulics. E2000 with laterals takes over 4 t of media and TH1600-2.5 is drawn 3,838 mm tall, so check floor loading, clear height and lifting routes first. Emaux lists lateral and nozzle internals and 2.5 / 4 bar ratings as separate codes with different media quantities, so do not mix their lists.
3 section citations
Scroll the table to see all fields; original units are retained.
| Model | Filter area | Flange | Media (0.5-0.8 / 1-2 mm, laterals) |
|---|---|---|---|
| Emaux E1050 | 0.86 m² | 80 mm / 3" | 859 / 272 kg |
| Emaux E1200 | 1.13 m² | 80 mm / 3" | 1075 / 428 kg |
| Emaux E1400 | 1.54 m² | 100 mm / 4" | 1495 / 498 kg |
| Emaux E1600 | 2.01 m² | 100 mm / 4" | 1997 / 949 kg |
| Emaux E1800 | 2.54 m² | 150 mm / 6" | 2366 / 1343 kg |
| Emaux E2000 | 3.14 m² | 150 mm / 6" | 2781 / 1375 kg |
| Emaux E2200 | 3.80 m² | 200 mm / 8" | 4568 / 1479 kg |
| Emaux TH1400-2.5 | 3.02 m² x2 | 160 mm / 6" | — |
| Emaux TH1600-2.5 | 3.36 m² x2 | 160 mm / 6" | — |
| Emaux TH2000-4.5 | 8.16 m² x2 | 200 mm / 8" | — |
| Emaux H3000-10.0 | 27.44 m² | 200/450 mm | — |
| Ouya SCD-1200 | 1.13 (unit printed as m) | 2 in | 860 kg sand |
| Ouya SCC-1200 | 1.17 (unit printed as m) | 2 in | 920 kg sand |
Heat pumps and starting blocks
Fairland rates its three heat pumps at the same condition (26 C air, 26 C water, 80% humidity): IXR110T 35 kW (40 kW boost), COP 16.3-6.6, 42.5-51.7 dB(A), 126 kg, running from -15 C; IPH150T 60 kW, COP 15.6-6.5, 54-62 dB(A), 243 kg; IPH300T 110 kW, COP 15.1-6.2, 56-65 dB(A), 431 kg, both IPH units down to -7 C. AO Ranking view: 26 C is the most favourable rating point and winter output drops markedly, so in cold regions ask for derating data at the local winter design temperature and plan a backup heat source; one large unit means fewer machines but a bigger loss when it stops. For starting blocks, Ouya CFT700 has an 805 x 630 mm top at 410 mm and CFT900 800 x 600 mm at 400 mm, both with a 9.5 degree top and five-position back plate; the page claims FINA 2017-2021 compliance, a publisher declaration.
5 section citations
Scroll the table to see all fields; original units are retained.
| Model | Heating | COP | Noise at 1 m | Net weight | Lowest ambient |
|---|---|---|---|---|---|
| Fairland IXR110T | 35 kW (40 kW boost) | 16.3-6.6 | 42.5-51.7 dB(A) | 126 kg | -15 C |
| Fairland IPH150T | 60 kW | 15.6-6.5 | 54-62 dB(A) | 243 kg | -7 C |
| Fairland IPH300T | 110 kW | 15.1-6.2 | 56-65 dB(A) | 431 kg | -7 C |
Standards and AO Ranking checklist
None of the 35 sources in this category declares a Chinese national standard; the only standard-type claim is the Ouya starting-block page stating compliance with FINA 2017-2021 starting-platform rules, a publisher declaration rather than certification. This guide therefore gives no national-standard table. AO Ranking checklist: (1) size pumps from maker curves using turnover and pipe losses, not ports alone; (2) lock the code that matches the local grid; (3) for sand filters, check floor loading, clear height and lifting before area; (4) get heat-pump derating at the winter design temperature; (5) for competition starting blocks, ask for World Aquatics approval or test documents; (6) obtain any tender-required test reports separately.
Sources & retrieval dates
- Ultra-Power_Commercial_Pump_Brochure_Singlepage_en_20251124.pdf ↗
- Chinese-language source page (www.ouyapool.com.cn) ↗
- Hydrau-Power-Commercial-Pump-Brochure_singlepage_en_20251126.pdf ↗
- Chinese-language source page (www.astralpool.com) ↗
- Chinese-language source page (www.astralpool.com) ↗
- Chinese-language source page (www.astralpool.com) ↗
- Commercial-Filter-Brochure-singlepage_en_20251202.pdf ↗
- Chinese-language source page (www.ouyapool.com.cn) ↗
- Chinese-language source page (www.fairlandgroup.com.cn) ↗
- Chinese-language source page (www.fairlandgroup.com.cn) ↗
- Chinese-language source page (www.fairlandgroup.com.cn) ↗
- Chinese-language source page (www.ouyapool.com.cn) ↗
- Chinese-language source page (www.ouyapool.com.cn) ↗
Documented source dates
- Source acquisition record
- Source acquisition record
- Source acquisition record
- Source acquisition record
- Source acquisition record
- Source acquisition record
- Source acquisition record