Fairland
Fairland IXR110T INVERX side-discharge inverter pool heat pump
Fairland IXR110T (INVERX side-discharge): 35.0 kW normal / 40.0 kW boost at 26/26°C/80% RH; COP 16.3–6.6; 42.5–51.7 dB(A) at 1 m; 1260×539×947 mm; 126 kg; ambient -15–43°C.
- Brand / publisher
- Fairland · Fairland Group (site attribution)
- Model
- IXR110T
- Category
- Pool equipment
- Region / configuration
- Region in original source · IXR110T
Up to 4 records; compare original sources without recommendations or performance ranks.
Models and configurations retain their source scope. Check specifications against the venue and intended use.
Scope
Identity type: published_catalogue_model_row; limited to dossier-captured page statements. No orderable SKU, independent certification, stock or install suitability inferred.
AO Ranking Review
Fairland IXR110T INVERX side-discharge inverter pool heat pump (Fairland product page): 35.0 kW normal and 40.0 kW boost heating (26 C air / 26 C water / 80% humidity); COP 16.3-6.6; 42.5-51.7 dB(A) at 1 m; 1260 x 539 x 947 mm, 126 kg; -15 to 43 C operating range; up to 40 C outlet water (per the page).
AO Ranking view: The smallest of the three, but with the highest peak COP, the lowest noise and a -15 C lower limit, 8 C below the -7 C of the two IPH units. The 539 mm depth and side discharge suit wall-side installation, making it a main heat source for small outdoor, villa or club pools.
Suitable settings
- Small villa and club pools
- Sites near housing that are noise-sensitive
- Outdoor pools in colder winter climates
Buying checklist
- Check capacity loss at the winter design temperature; 26 C rating data is optimistic
- Confirm power supply and distance to noise-sensitive neighbours
- The source declares no national standard or certification; obtain any required test reports separately
Peer comparison
Three Fairland heat pumps in the library, all at 26 C air, 26 C water, 80% humidity: IXR110T 35 kW (40 kW boost), COP 16.3-6.6, 42.5-51.7 dB(A), 126 kg; IPH150T 60 kW, COP 15.6-6.5, 54-62 dB(A), 243 kg; IPH300T 110 kW, COP 15.1-6.2, 56-65 dB(A), 431 kg.
Source-scoped parameters
Heating capacity (normal mode)
35.0 kW (conditions: air 26°C / water 26°C / humidity 80%)
Original scope conditions
Publisher-reported catalogue statement only; not independent certification, orderability, stock, install adequacy or live SKU acceptance. Box-fetched 2026-10-31; re-verified from CN (Mac) egress 2026-10-31, HTTP 200.
Heating capacity (boost mode)
40.0 kW (same operating condition)
Original scope conditions
Publisher-reported catalogue statement only; not independent certification, orderability, stock, install adequacy or live SKU acceptance. Box-fetched 2026-10-31; re-verified from CN (Mac) egress 2026-10-31, HTTP 200.
COP
16.3~6.6
Original scope conditions
Publisher-reported catalogue statement only; not independent certification, orderability, stock, install adequacy or live SKU acceptance. Box-fetched 2026-10-31; re-verified from CN (Mac) egress 2026-10-31, HTTP 200.
Noise at 1 m
42.5~51.7 dB(A)
Original scope conditions
Publisher-reported catalogue statement only; not independent certification, orderability, stock, install adequacy or live SKU acceptance. Box-fetched 2026-10-31; re-verified from CN (Mac) egress 2026-10-31, HTTP 200.
Dimensions L×W×H
1260×539×947 mm
Original scope conditions
Publisher-reported catalogue statement only; not independent certification, orderability, stock, install adequacy or live SKU acceptance. Box-fetched 2026-10-31; re-verified from CN (Mac) egress 2026-10-31, HTTP 200.
Net weight
126 kg
Original scope conditions
Publisher-reported catalogue statement only; not independent certification, orderability, stock, install adequacy or live SKU acceptance. Box-fetched 2026-10-31; re-verified from CN (Mac) egress 2026-10-31, HTTP 200.
Operating ambient temperature
-15~43℃
Original scope conditions
Publisher-reported catalogue statement only; not independent certification, orderability, stock, install adequacy or live SKU acceptance. Box-fetched 2026-10-31; re-verified from CN (Mac) egress 2026-10-31, HTTP 200.
Outlet water temperature
Page states up to 40℃
Original scope conditions
Publisher-reported catalogue statement only; not independent certification, orderability, stock, install adequacy or live SKU acceptance. Box-fetched 2026-10-31; re-verified from CN (Mac) egress 2026-10-31, HTTP 200.
| Parameter | Original value & unit | Conditions, scope & source |
|---|---|---|
| Heating capacity (normal mode) | 35.0 kW (conditions: air 26°C / water 26°C / humidity 80%) | Original scope conditionsPublisher-reported catalogue statement only; not independent certification, orderability, stock, install adequacy or live SKU acceptance. Box-fetched 2026-10-31; re-verified from CN (Mac) egress 2026-10-31, HTTP 200. IXR110T Open source ↗ |
| Heating capacity (boost mode) | 40.0 kW (same operating condition) | Original scope conditionsPublisher-reported catalogue statement only; not independent certification, orderability, stock, install adequacy or live SKU acceptance. Box-fetched 2026-10-31; re-verified from CN (Mac) egress 2026-10-31, HTTP 200. IXR110T Open source ↗ |
| COP | 16.3~6.6 | Original scope conditionsPublisher-reported catalogue statement only; not independent certification, orderability, stock, install adequacy or live SKU acceptance. Box-fetched 2026-10-31; re-verified from CN (Mac) egress 2026-10-31, HTTP 200. IXR110T Open source ↗ |
| Noise at 1 m | 42.5~51.7 dB(A) | Original scope conditionsPublisher-reported catalogue statement only; not independent certification, orderability, stock, install adequacy or live SKU acceptance. Box-fetched 2026-10-31; re-verified from CN (Mac) egress 2026-10-31, HTTP 200. IXR110T Open source ↗ |
| Dimensions L×W×H | 1260×539×947 mm | Original scope conditionsPublisher-reported catalogue statement only; not independent certification, orderability, stock, install adequacy or live SKU acceptance. Box-fetched 2026-10-31; re-verified from CN (Mac) egress 2026-10-31, HTTP 200. IXR110T Open source ↗ |
| Net weight | 126 kg | Original scope conditionsPublisher-reported catalogue statement only; not independent certification, orderability, stock, install adequacy or live SKU acceptance. Box-fetched 2026-10-31; re-verified from CN (Mac) egress 2026-10-31, HTTP 200. IXR110T Open source ↗ |
| Operating ambient temperature | -15~43℃ | Original scope conditionsPublisher-reported catalogue statement only; not independent certification, orderability, stock, install adequacy or live SKU acceptance. Box-fetched 2026-10-31; re-verified from CN (Mac) egress 2026-10-31, HTTP 200. IXR110T Open source ↗ |
| Outlet water temperature | Page states up to 40℃ | Original scope conditionsPublisher-reported catalogue statement only; not independent certification, orderability, stock, install adequacy or live SKU acceptance. Box-fetched 2026-10-31; re-verified from CN (Mac) egress 2026-10-31, HTTP 200. IXR110T Open source ↗ |
Sources & retrieval dates
Documented source dates
- Source acquisition record