Fairland
Fairland IPH300T commercial inverter pool heat pump
Fairland IPH300T commercial inverter pool heat pump: 110.0 kW at 26/26°C/80% RH; COP 15.1–6.2; 56.0–65.0 dB(A) at 1 m; 2100×1090×1280 mm; 431 kg. Ambient range from merged table cell / series text.
- Brand / publisher
- Fairland · Fairland Group (site attribution)
- Model
- IPH300T
- Category
- Pool equipment
- Region / configuration
- Region in original source · IPH300T
Up to 4 records; compare original sources without recommendations or performance ranks.
Models and configurations retain their source scope. Check specifications against the venue and intended use.
Scope
Identity type: published_catalogue_model_row; limited to dossier-captured page statements. No orderable SKU, independent certification, stock or install suitability inferred.
AO Ranking Review
Fairland IPH300T commercial inverter pool heat pump (Fairland product page): 110.0 kW heating (26 C air / 26 C water / 80% humidity); COP 15.1-6.2; 56.0-65.0 dB(A) at 1 m; 2100 x 1090 x 1280 mm, 431 kg; the series page cites -7 to 43 C operation; spiral titanium heat exchanger.
AO Ranking view: About 1.83 times the output of IPH150T, with nearly double the length (2100 versus 1110 mm), 431 versus 243 kg, and a noise ceiling 3 dB(A) higher. One large unit cuts unit count and pipe connections, but losing it takes a bigger share of the load, so large pools usually still need a standby (AO Ranking view).
Suitable settings
- Central heating for large public and competition pools
- Large units on roof or outdoor equipment platforms
Buying checklist
- Check capacity loss at the winter design temperature; 26 C rating data is optimistic
- Confirm power supply and distance to noise-sensitive neighbours
- The source declares no national standard or certification; obtain any required test reports separately
- At 431 kg, check roof or platform loading
Peer comparison
Three Fairland heat pumps in the library, all at 26 C air, 26 C water, 80% humidity: IXR110T 35 kW (40 kW boost), COP 16.3-6.6, 42.5-51.7 dB(A), 126 kg; IPH150T 60 kW, COP 15.6-6.5, 54-62 dB(A), 243 kg; IPH300T 110 kW, COP 15.1-6.2, 56-65 dB(A), 431 kg.
Source-scoped parameters
Heating capacity
110.0 kW (conditions: air 26°C / water 26°C / humidity 80%)
Original scope conditions
Publisher-reported catalogue statement only; not independent certification, orderability, stock, install adequacy or live SKU acceptance. Box-fetched 2026-10-31; re-verified from CN (Mac) egress 2026-10-31, HTTP 200.
COP
15.1~6.2 (same operating condition)
Original scope conditions
Publisher-reported catalogue statement only; not independent certification, orderability, stock, install adequacy or live SKU acceptance. Box-fetched 2026-10-31; re-verified from CN (Mac) egress 2026-10-31, HTTP 200.
Noise at 1 m
56.0~65.0 dB(A)
Original scope conditions
Publisher-reported catalogue statement only; not independent certification, orderability, stock, install adequacy or live SKU acceptance. Box-fetched 2026-10-31; re-verified from CN (Mac) egress 2026-10-31, HTTP 200.
Dimensions L×W×H
2100×1090×1280 mm
Original scope conditions
Publisher-reported catalogue statement only; not independent certification, orderability, stock, install adequacy or live SKU acceptance. Box-fetched 2026-10-31; re-verified from CN (Mac) egress 2026-10-31, HTTP 200.
Net weight
431 kg
Original scope conditions
Publisher-reported catalogue statement only; not independent certification, orderability, stock, install adequacy or live SKU acceptance. Box-fetched 2026-10-31; re-verified from CN (Mac) egress 2026-10-31, HTTP 200.
Operating ambient temperature
Merged table cell; series page states -7℃~43℃
Original scope conditions
Publisher-reported catalogue statement only; not independent certification, orderability, stock, install adequacy or live SKU acceptance. Box-fetched 2026-10-31; re-verified from CN (Mac) egress 2026-10-31, HTTP 200.
Heat exchanger
Spiral titanium heat exchanger
Original scope conditions
Publisher-reported catalogue statement only; not independent certification, orderability, stock, install adequacy or live SKU acceptance. Box-fetched 2026-10-31; re-verified from CN (Mac) egress 2026-10-31, HTTP 200.
| Parameter | Original value & unit | Conditions, scope & source |
|---|---|---|
| Heating capacity | 110.0 kW (conditions: air 26°C / water 26°C / humidity 80%) | Original scope conditionsPublisher-reported catalogue statement only; not independent certification, orderability, stock, install adequacy or live SKU acceptance. Box-fetched 2026-10-31; re-verified from CN (Mac) egress 2026-10-31, HTTP 200. IPH300T Open source ↗ |
| COP | 15.1~6.2 (same operating condition) | Original scope conditionsPublisher-reported catalogue statement only; not independent certification, orderability, stock, install adequacy or live SKU acceptance. Box-fetched 2026-10-31; re-verified from CN (Mac) egress 2026-10-31, HTTP 200. IPH300T Open source ↗ |
| Noise at 1 m | 56.0~65.0 dB(A) | Original scope conditionsPublisher-reported catalogue statement only; not independent certification, orderability, stock, install adequacy or live SKU acceptance. Box-fetched 2026-10-31; re-verified from CN (Mac) egress 2026-10-31, HTTP 200. IPH300T Open source ↗ |
| Dimensions L×W×H | 2100×1090×1280 mm | Original scope conditionsPublisher-reported catalogue statement only; not independent certification, orderability, stock, install adequacy or live SKU acceptance. Box-fetched 2026-10-31; re-verified from CN (Mac) egress 2026-10-31, HTTP 200. IPH300T Open source ↗ |
| Net weight | 431 kg | Original scope conditionsPublisher-reported catalogue statement only; not independent certification, orderability, stock, install adequacy or live SKU acceptance. Box-fetched 2026-10-31; re-verified from CN (Mac) egress 2026-10-31, HTTP 200. IPH300T Open source ↗ |
| Operating ambient temperature | Merged table cell; series page states -7℃~43℃ | Original scope conditionsPublisher-reported catalogue statement only; not independent certification, orderability, stock, install adequacy or live SKU acceptance. Box-fetched 2026-10-31; re-verified from CN (Mac) egress 2026-10-31, HTTP 200. IPH300T Open source ↗ |
| Heat exchanger | Spiral titanium heat exchanger | Original scope conditionsPublisher-reported catalogue statement only; not independent certification, orderability, stock, install adequacy or live SKU acceptance. Box-fetched 2026-10-31; re-verified from CN (Mac) egress 2026-10-31, HTTP 200. IPH300T Open source ↗ |
Sources & retrieval dates
Documented source dates
- Source acquisition record