AO Buying Guide | Sports floodlights: flux calculated at 150 lm/W and flux stated per configuration do not belong in one table

Comparing 25 TPK configurations in four series with eight Signify OptiVision order codes: TPK calculates flux at 150 lm/W, while Signify states flux per configuration, with efficacy varying from 119 to 148 lm/W by optic; one gives lifetime in hours only, the other L90/L96. YXYSW5-E1000W shares the E800W mass, still so on re-check, and needs written confirmation.

Record date (source acquisition dates below) Nov 9, 2026 · Original editorial and source-scope review

Scope

AO Ranking buying guide based on sourced manufacturer statements already in the library; not a test, ranking or certification conclusion.

TPK: four series, 25 configurations

SeriesPower steps (publisher)Luminous flux (publisher)LengthMassCCT/CRIBeam optionsControl
TPK YXYSW5200-1200 W, 6 steps30,000-180,000 lm150-776 mm6.2-32.6 kg3000-6500 K; CRI 70+/8035/45/60/90 deg, 140x80 deg, asymmetricDALI/DMX
TPK YXYSW6400-1200 W, 6 steps60,000-180,000 lm522/681 mm22/36 kg2700-6500 K; CRI 70+/80+/90+10/15/25/45/60/90 deg1-10V/DALI/DMX
TPK YXYSW7400-1800 W, 8 steps60,000-270,000 lm718/732 mm18/33/45 kg3000-6500 K; CRI 70+/80+10/25/45/60/90 deg, asymmetric 60 degDALI/DMX/1-10V
TPK YXYSW8240/300-1200/1500 W, 5 steps36,000-225,000 lm250-918 mm7.7-29.5 kg3000-6500 K10/15/25/45/60/90 deg, asymmetric 60 degDALI/DMX

All four series state IP66, IK08 and an operating range of -35 to +50 C; lifetime is 60,000 hours for YXYSW5 to 7 and 50,000 hours for YXYSW8; warranty five years.

AO Ranking view: TPK's luminous flux is 'calculated at 150 lm/W', not stated per configuration. The page says so itself, which means all 25 configurations show 150 lm/W and no difference between optics or colour temperatures can be seen. Comparing efficacy against a brand that states flux per configuration mixes two bases. Separately, YXYSW5-E1000W is 113 mm longer than the E800W and ships in a larger carton, yet both are listed at 20.45 kg; a re-check of the official page through a mainland China connection on 9 November 2026 found the same figure, so the library records it as published, and buyers should get written confirmation.

6 section citations

Signify OptiVision: figures per configuration

Order code (summary)PowerLuminous fluxEfficacyCCTCRIBeamNet massLumen maintenance
BVP518 1720/740 ... OUT1000 W149,640 lm148 lm/W4000 K705-13 x 120 deg27 kgL96 at 50,000 h; L90 at 100,000 h
BVP518 1720/740 ... OUT LO1000 W120,400 lm119 lm/W4000 K705-13 x 120 deg27 kgSame
BVP518 1720/757 HGB ...1000 W149,640 lm148 lm/W5700 K705-13 x 120 deg27 kgSame
BVP528 2830/757 PSD ... NB1670 W240,007 lm144 lm/W5700 K>705-11 x 78 deg33 kgL90 at 50,000 h and 100,000 h
BVP528 2830/757 PSD ... WB1670 W236,846 lm142 lm/W5700 K>705-11 x 78 deg33 kgSame
BVP528 2830/757 PSD ... XWB1670 W233,797 lm140 lm/W5700 K>705-11 x 78 deg33 kgSame

All eight configurations state IP66, IK08, 230-400 V, dimmable through a DALI interface and an upward light ratio of 0.

AO Ranking view: Signify states flux per configuration, so you can see efficacy change with optics at the same power. Among 1000 W BVP518 units, the 'LO' configuration gives 119 lm/W and the standard one 148 lm/W; the 1670 W BVP528 with narrow, wide and extra-wide optics runs from 140 to 144 lm/W. None of this shows under a 'calculated at 150 lm/W' approach. Lifetime is also written differently: Signify gives L90 or L96 with hours, stating how much light remains at that point, while TPK gives 'lifetime 60,000 hours' without a lumen maintenance condition, so the two cannot be compared directly.

6 section citations
  • Exact-code fact sheet 912300060903 ↗www.signify.com · Retrieved Oct 1, 2026 Library product record BVP518 1720/740 BV A35-WB D9 T35 OUT (record-466ac8590fe67ef2): publisher page as captured; figures as stored in the record
  • Exact-code fact sheet 912300060905 ↗www.signify.com · Retrieved Oct 1, 2026 Library product record BVP518 1720/740 BV A35-WB D9 T35 OUT LO (record-d925f3be0b2a5197): publisher page as captured; figures as stored in the record
  • Exact-code fact sheet 912300060904 ↗www.signify.com · Retrieved Oct 1, 2026 Library product record BVP518 1720/757 HGB A35-WB D9 T35 OUT (record-055e863b28b15e29): publisher page as captured; figures as stored in the record
  • Exact-code fact sheet 912300060883 ↗www.signify.com · Retrieved Oct 1, 2026 Library product record BVP528 2830/757 PSD BV A35-NB D9 T25 OUT (record-7ccbd6a7037e011f): publisher page as captured; figures as stored in the record
  • Exact-code fact sheet 912300060882 ↗www.signify.com · Retrieved Oct 1, 2026 Library product record BVP528 2830/757 PSD BV A35-WB D9 T25 OUT (record-a7a03501f5021f73): publisher page as captured; figures as stored in the record
  • Exact-code fact sheet 912300060884 ↗www.signify.com · Retrieved Oct 1, 2026 Library product record BVP528 2830/757 PSD BV A35-XWB D9 T25OUT (record-c36004863bb131ea): publisher page as captured; figures as stored in the record

Buying points

Buying pointWhyStatus in this sample
Ask for per-configuration flux and photometric files (IES/LDT)Illuminance is calculated from photometric files, not wattageTPK gives calculated values; Signify gives per-configuration figures
State the lumen maintenance condition (for example L90 at 50,000 h)'Lifetime' alone cannot be comparedTPK gives no condition; Signify does
Ask for flicker figuresCritical where there is TV broadcast or high-speed filmingNot present in either brand's library records
Match beam angle to mounting height and throwHigh masts with long throw need narrow beams; low, close mounting needs wide onesTPK's narrowest is 10 deg (YXYSW6 to 8), YXYSW5's narrowest 35 deg; Signify from 5-13 deg
Confirm mass and mounting hardwareDecides pole and bracket loadingTPK E1000W mass is doubtful and needs written confirmation

AO Ranking view: lighting design comes before choosing the luminaire. At the same 1000 W, different optics can give very different illuminance and uniformity on the field; without a lighting calculation, comparing flux and efficacy alone means little. For broadcast-related requirements such as flicker and colour rendering, see the library's explainer on national standards for sports LED lighting and LED displays.

2 section citations

What this guide leaves out

  • This guide compares 33 configurations from two brands. SCL's six records in the library currently carry no parameters and are not included; nine records from Beauty Water, SHUA and Kangqiang that mention lights but are pool or fitness products are not sports lighting and are also excluded.
  • No brand ranking, prices or sales. All figures are publisher statements; AO Ranking has not tested them.
1 section citations

Sources & retrieval dates

  • TPK YXYSW5 stadium light (official page) ↗www.tpk-led.com · Retrieved Nov 9, 2026 Read-only re-check via CN egress 2026-11-09: model configuration table, E800W and E1000W both list Weight 20.45 KG; series spec block IP66, IK08, -35 to +50 C
  • Chinese-language source page (www.tpk-led.com) ↗www.tpk-led.com · Retrieved Nov 1, 2026 Library product record YXYSW5-E200W (record-4d795998c00c5fe2): publisher page as captured; figures as stored in the record
  • Chinese-language source page (www.tpk-led.com) ↗www.tpk-led.com · Retrieved Nov 1, 2026 Library product record YXYSW5-E1000W (record-28070d413051eb4c): publisher page as captured; figures as stored in the record
  • Chinese-language source page (www.tpk-led.com) ↗www.tpk-led.com · Retrieved Nov 1, 2026 Library product record YXYSW6-A400W (record-d1c771613665738c): publisher page as captured; figures as stored in the record
  • Chinese-language source page (www.tpk-led.com) ↗www.tpk-led.com · Retrieved Nov 1, 2026 Library product record YXYSW7-G1800W (record-e7d83c8fb7232a16): publisher page as captured; figures as stored in the record
  • Chinese-language source page (www.tpk-led.com) ↗www.tpk-led.com · Retrieved Nov 1, 2026 Library product record YXYSW8-H300W (record-2c5fc649c7d3a69f): publisher page as captured; figures as stored in the record
  • Exact-code fact sheet 912300060903 ↗www.signify.com · Retrieved Oct 1, 2026 Library product record BVP518 1720/740 BV A35-WB D9 T35 OUT (record-466ac8590fe67ef2): publisher page as captured; figures as stored in the record
  • Exact-code fact sheet 912300060905 ↗www.signify.com · Retrieved Oct 1, 2026 Library product record BVP518 1720/740 BV A35-WB D9 T35 OUT LO (record-d925f3be0b2a5197): publisher page as captured; figures as stored in the record
  • Exact-code fact sheet 912300060904 ↗www.signify.com · Retrieved Oct 1, 2026 Library product record BVP518 1720/757 HGB A35-WB D9 T35 OUT (record-055e863b28b15e29): publisher page as captured; figures as stored in the record
  • Exact-code fact sheet 912300060883 ↗www.signify.com · Retrieved Oct 1, 2026 Library product record BVP528 2830/757 PSD BV A35-NB D9 T25 OUT (record-7ccbd6a7037e011f): publisher page as captured; figures as stored in the record
  • Exact-code fact sheet 912300060882 ↗www.signify.com · Retrieved Oct 1, 2026 Library product record BVP528 2830/757 PSD BV A35-WB D9 T25 OUT (record-a7a03501f5021f73): publisher page as captured; figures as stored in the record
  • Exact-code fact sheet 912300060884 ↗www.signify.com · Retrieved Oct 1, 2026 Library product record BVP528 2830/757 PSD BV A35-XWB D9 T25OUT (record-c36004863bb131ea): publisher page as captured; figures as stored in the record