Industry Indices
← Research & analysis
Court & competition equipment

Research

Original research analysis

AO Buying Guide | Track anemometers and three-sided wind-speed displays: separate the sensor from the display

|Model|Manufacturer product identity|Manufacturer specification|Manufacturer key statements| |---|---|---|---| |TQW-C015|Ultrasonic anemometer|200 × 200 × 300 mm (axes unspecified)|Ultrasonic wind-speed measurement; stat…

Record date (source acquisition dates below) Nov 9, 2026 · Original editorial and source-scope review

Scope

AO Ranking buying guide based on captured manufacturer product-page statements; not a test, ranking or certification conclusion.

Two models are not interchangeable pieces of the same device

ModelManufacturer product identityManufacturer specificationManufacturer key statements
TQW-C015Ultrasonic anemometer200 × 200 × 300 mm (axes unspecified)Ultrasonic wind-speed measurement; stated accuracy 0.1 m/s; supports manual and automatic track wind-speed and direction tests with synchronous display; install according to the anemometer arrow; wired/wireless communication; operating voltage AC 220 V / DC 24 V; operating temperature -15 °C to 65 °C; the text says a three-sided wind-speed display is supplied as a companion, without naming the display model
TQW-S024Three-sided wind-speed display900 × 900 × 750 mm (axes unspecified)Three-sided high-brightness LED display; waterproof and dustproof; movable; display method is high-brightness LED numeric tubes; serial output RS485; data transmission wireless RF200; operating voltage AC 110–240 V 50 Hz; the page does not state a binding to TQW-C015

AO judgement: split the measuring unit and the display into two procurement packages. TQW-C015 is a wind-speed and direction measuring device; TQW-S024 is a three-sided display. The C015 page’s phrase about a companion three-sided wind-speed display only shows that the catalogue mentions a companion screen; it does not give the screen’s model. TQW-C015 does not appear anywhere on the S024 page. The two pages cannot be rewritten as a confirmed paired shipment. Obtain written confirmation of the binding, whether they ship as a set, and whether the interfaces interoperate.

2 section citations

Useful comparisons

  • None of the three sides is labelled with an axis. Keep “200 × 200 × 300” and “900 × 900 × 750” as three source figures; do not map them onto confirmed length, width and height. Add a sentence stating which side is mounting height, the windward face or the base before acceptance.
  • Accuracy is a catalogue claim, not a measurement. “0.1 m/s” may be used as a request-for-quote check, not as an AO test result and not as a ranking score. This article does not fill in competition wind limits.
  • Communication figures do not prove a working link. C015 only states “wired/wireless” and gives no protocol identity; S024 states RS485 and wireless RF200. The catalogue does not prove that the two already interoperate.
  • Power supplies also need separate checks. C015 is listed as AC 220 V / DC 24 V; S024 as AC 110–240 V 50 Hz. Do not assume one supply can run the whole set.
  • Marketing language was not adopted. The C015 phrase “industrial-grade measuring module” has no quantified meaning and does not enter the parameter table. S024 states that it is waterproof and dustproof but gives no ingress-protection code; do not invent an IP rating.
2 section citations

Do not confuse neighbouring products

NeighbourWhy it does not belong in this table
TQW-S023 three-sided lap-counter display (/product/926.html)Manufacturer specification 560 × 560 × 400 mm (axes unspecified); a copper bell hung at the bottom of the lap-counter screen; outdoor high-brightness LED numeric lap counter; 2 LED digits, 3 display faces, numbers 0–99. The model, envelope and purpose all differ from TQW-S024. Sharing the word “three-sided” does not make them the same display
Delay/countdown display TQW-S003An existing neighbouring product used for minute-second countdown / start-delay display. This article did not open that product page and cites no dimensions for it; the only point here is not to merge it with the wind-speed display as a single SKU
C16 venue LED boardsAudience content displays, not trackside wind-reading displays

Photofinish systems, finish-line infrared beam-break devices and field electronic distance measurement (see the other guide in this folder) also stay outside this table.

2 section citations

Put undisclosed details into contract attachments, not invented facts

Before ordering, separately request: the display model bound to C015 and whether they ship as a set; definitions of installation orientation and mounting height; the concrete wired/wireless protocol and any results-system interface; an ingress rating for S024 if the project needs one; and power and incoming-inspection methods for both units. No explicit standard number or conformity certificate was found in these captured product details, so no `declared` standard conclusion is assigned. Project rules, editions and testing documents still need project-specific technical verification.

2 section citations

Original sources and evidence

  1. TQW-C015: https://www.taishansports.com.cn/product/934.html
  2. TQW-S024: https://www.taishansports.com.cn/product/925.html
  3. Contrast TQW-S023: https://www.taishansports.com.cn/product/926.html

See `parameter-evidence.csv` in this folder for field-level evidence and retrieval times. Raw HTML is internal reference, not for public redistribution. Check the “详情介绍” sections of `text/934.txt`, `925.txt` and `926.txt`. Guide deduplication key: `guide|track-anemometer-and-wind-display`. Before integration, compare against the current library’s anemometer/display topic and update evidence for existing models; do not insert this article together with the C35 question skeleton.

2 section citations

Sources & retrieval dates

Documented source dates

  1. Source acquisition record