Research
AO Buying Guide | Track anemometers and three-sided wind-speed displays: separate the sensor from the display
|Model|Manufacturer product identity|Manufacturer specification|Manufacturer key statements| |---|---|---|---| |TQW-C015|Ultrasonic anemometer|200 × 200 × 300 mm (axes unspecified)|Ultrasonic wind-speed measurement; stat…
Scope
AO Ranking buying guide based on captured manufacturer product-page statements; not a test, ranking or certification conclusion.
Two models are not interchangeable pieces of the same device
| Model | Manufacturer product identity | Manufacturer specification | Manufacturer key statements |
|---|---|---|---|
| TQW-C015 | Ultrasonic anemometer | 200 × 200 × 300 mm (axes unspecified) | Ultrasonic wind-speed measurement; stated accuracy 0.1 m/s; supports manual and automatic track wind-speed and direction tests with synchronous display; install according to the anemometer arrow; wired/wireless communication; operating voltage AC 220 V / DC 24 V; operating temperature -15 °C to 65 °C; the text says a three-sided wind-speed display is supplied as a companion, without naming the display model |
| TQW-S024 | Three-sided wind-speed display | 900 × 900 × 750 mm (axes unspecified) | Three-sided high-brightness LED display; waterproof and dustproof; movable; display method is high-brightness LED numeric tubes; serial output RS485; data transmission wireless RF200; operating voltage AC 110–240 V 50 Hz; the page does not state a binding to TQW-C015 |
AO judgement: split the measuring unit and the display into two procurement packages. TQW-C015 is a wind-speed and direction measuring device; TQW-S024 is a three-sided display. The C015 page’s phrase about a companion three-sided wind-speed display only shows that the catalogue mentions a companion screen; it does not give the screen’s model. TQW-C015 does not appear anywhere on the S024 page. The two pages cannot be rewritten as a confirmed paired shipment. Obtain written confirmation of the binding, whether they ship as a set, and whether the interfaces interoperate.
Useful comparisons
- None of the three sides is labelled with an axis. Keep “200 × 200 × 300” and “900 × 900 × 750” as three source figures; do not map them onto confirmed length, width and height. Add a sentence stating which side is mounting height, the windward face or the base before acceptance.
- Accuracy is a catalogue claim, not a measurement. “0.1 m/s” may be used as a request-for-quote check, not as an AO test result and not as a ranking score. This article does not fill in competition wind limits.
- Communication figures do not prove a working link. C015 only states “wired/wireless” and gives no protocol identity; S024 states RS485 and wireless RF200. The catalogue does not prove that the two already interoperate.
- Power supplies also need separate checks. C015 is listed as AC 220 V / DC 24 V; S024 as AC 110–240 V 50 Hz. Do not assume one supply can run the whole set.
- Marketing language was not adopted. The C015 phrase “industrial-grade measuring module” has no quantified meaning and does not enter the parameter table. S024 states that it is waterproof and dustproof but gives no ingress-protection code; do not invent an IP rating.
Do not confuse neighbouring products
| Neighbour | Why it does not belong in this table |
|---|---|
| TQW-S023 three-sided lap-counter display (/product/926.html) | Manufacturer specification 560 × 560 × 400 mm (axes unspecified); a copper bell hung at the bottom of the lap-counter screen; outdoor high-brightness LED numeric lap counter; 2 LED digits, 3 display faces, numbers 0–99. The model, envelope and purpose all differ from TQW-S024. Sharing the word “three-sided” does not make them the same display |
| Delay/countdown display TQW-S003 | An existing neighbouring product used for minute-second countdown / start-delay display. This article did not open that product page and cites no dimensions for it; the only point here is not to merge it with the wind-speed display as a single SKU |
| C16 venue LED boards | Audience content displays, not trackside wind-reading displays |
Photofinish systems, finish-line infrared beam-break devices and field electronic distance measurement (see the other guide in this folder) also stay outside this table.
Put undisclosed details into contract attachments, not invented facts
Before ordering, separately request: the display model bound to C015 and whether they ship as a set; definitions of installation orientation and mounting height; the concrete wired/wireless protocol and any results-system interface; an ingress rating for S024 if the project needs one; and power and incoming-inspection methods for both units. No explicit standard number or conformity certificate was found in these captured product details, so no `declared` standard conclusion is assigned. Project rules, editions and testing documents still need project-specific technical verification.
Original sources and evidence
- TQW-C015: https://www.taishansports.com.cn/product/934.html
- TQW-S024: https://www.taishansports.com.cn/product/925.html
- Contrast TQW-S023: https://www.taishansports.com.cn/product/926.html
See `parameter-evidence.csv` in this folder for field-level evidence and retrieval times. Raw HTML is internal reference, not for public redistribution. Check the “详情介绍” sections of `text/934.txt`, `925.txt` and `926.txt`. Guide deduplication key: `guide|track-anemometer-and-wind-display`. Before integration, compare against the current library’s anemometer/display topic and update evidence for existing models; do not insert this article together with the C35 question skeleton.
Sources & retrieval dates
- Chinese-language source page (www.taishansports.com.cn) ↗
- Chinese-language source page (www.taishansports.com.cn) ↗
Documented source dates
- Source acquisition record