1. Horizontal Lux vs. Vertical Camera-Facing Lux
General buildings measure only horizontal floor lux (Eh), but televised sports film vertical athletes and airborne balls. JGJ 153-2016 defines Classes I through VI—for televised tiers (IV–VI), vertical illuminance toward the main camera (Ev) and its uniformity govern broadcast quality.
2. JGJ 153-2016 Six Lighting Classes at a Glance
Reference hierarchy across outdoor football stadiums and indoor multipurpose arenas:
2 section citations
Scroll the table to see all fields; original units are retained.
| JGJ 153 Class | Typical Venue Use | Reference Illuminance Band | CRI & Glare Limits |
|---|---|---|---|
| Class I | School PE, community & recreational play | Outdoor football Eh ≥150–200 lx; indoor ≥200–300 lx | CRI ≥65–70; outdoor GR ≤55 |
| Class II | Amateur matches, college training & commercial clubs | Outdoor football Eh ≥300 lx; indoor ≥500 lx | CRI ≥70–80; outdoor GR ≤50 |
| Class III | Professional competition (non-televised) | Outdoor football Eh ≥500 lx; indoor ≥750 lx | CRI ≥80; uniformity U1 ≥0.5–0.6, U2 ≥0.7 |
| Class IV | National events / SD TV broadcast | Main-camera vertical Ev ≥750–1,000 lx | CRI ≥80; strict flicker & shadow control |
| Class V | Major international events / HDTV broadcast | Main-camera vertical Ev ≥1,400–1,500 lx | CRI ≥80–90 (≥85–90 preferred); slow-motion flicker limits |
| Class VI | Olympics / World Cup / 4K UHD broadcast | Main-camera Ev ≥2,000 lx across multi-camera planes | CRI ≥90 (TLCI ≥85–90); uninterruptible instant backup |
3. Night-Time Commissioning Must Measure Lux, CRI & Flicker On-Site
DIALux simulation renderings never substitute for dark-sky / blackout grid measurements of U1, U2, CRI, and flicker at commissioning.
Sources & retrieval dates
- Chinese-language source page (ebook.chinabuilding.com.cn) ↗
- Signify Philips ArenaVision LED gen3.5 Technical Leaflet ↗
- Chinese-language source page (cn.unilumin.com) ↗
- Chinese-language source page (std.samr.gov.cn) ↗
Documented source dates
- Source acquisition record