National standards
Standards Explained | CJJ 122-2017 Swimming Pool Water Engineering Code: Turnover, Filtration Velocity & Plant Sizing
Breaks down China’s authoritative pool engineering code CJJ 122-2017 alongside GB 37488-2019—covering turnover times by pool type, sand-filter velocity ceilings, reverse-flow overflow design, and pump/filter sizing audits.
Scope
Intended for natatorium owners, MEP water engineers, and commercial pool-equipment buyers.
1. Why Pools Turn Cloudy or Irritating: Slow Turnover & Over-Driven Filters
Undersized sand filters paired with oversized pumps push filtration velocity above 45–50 m/h, blowing fine particulates straight back into the pool and forcing operators to overdose chlorine. CJJ 122-2017 enforces strict turnover and velocity ceilings to prevent this.
2. Turnover & Filter Sizing Matrix Under CJJ 122-2017
Use this table to audit whether a vendor’s filter-vessel count and area are properly sized:
2 section citations
Scroll the table to see all fields; original units are retained.
| Pool Type | Typical Turnover Time | Circulation Mode | Plant-Room Audit Checks |
|---|---|---|---|
| Competition Pool (50 m) | 4 – 6 hours | Reverse flow (floor inlets, perimeter overflow) | Dedicated balance tank; size filter area at 20–30 m/h velocity across ≥2 parallel vessels |
| Public / University Pool | 3 – 4 hours (high bather load) | Reverse or mixed circulation | ≥2 operating pumps + 1 standby; add VFDs for overnight setback |
| Children’s / Toddlers’ Pool | 1 – 2 hours (high contamination load) | 100% independent loop (NEVER share with adult pool) | Dedicated high-turnover filtration + UV/low-chlorine loop |
| Thermal SPA / Hydrotherapy | 0.25 – 0.5 hours (15–30 min) | Dedicated loop + rapid fresh-water dilution | High water temp depletes chlorine rapidly; mandate 24/7 automated ORP/pH dosing |
3. A One-Minute Formula to Catch Undersized Sand Filters
Quick audit formula: Required filter area (m²) = Pool volume (m³) ÷ Turnover (h) ÷ Design velocity (~25 m/h). For a 1,250 m³ pool on a 4-hour turnover (312.5 m³/h), you need at least 12.5 m² of total filter area—instantly exposing undersized bids.