Avant
Avant Magnus in-ground retractable seating system
Avant Magnus in-ground retractable seating system: One drive per group of 4 seats (the introduction also says 4 / 6 / 8 seats); a standard stowed size of 428 × 1760 × 2290 mm per group, a 220 mm deck height when deployed, a suggested opening of 1200-1400 mm (total step width per group) and a suggested pit depth of 430-600 mm (box height); 350-450 W main motor power; wireless control from a tablet; and the Avant Haosheng rear-mounted upholstered seat as the recommended seat.
- Brand / publisher
- Avant · Avant Sports Industrial Co., Ltd.
- Model
- See record title
- Category
- Venue equipment
- Region / configuration
- Region in original source · Configuration in original source
Up to 4 records; compare original sources without recommendations or performance ranks.
Models and configurations retain their source scope. Check specifications against the venue and intended use.
Scope
Identity type: published_catalogue_model; limited to statements on the official product page. No orderable SKU, independent certification, stock or install suitability inferred.
AO Ranking Review
Avant Magnus is an in-ground retractable seating system in the telescopic-stand section: seats fold under the floor and the deck becomes the walkway between rows when deployed. The publisher page lists one drive per group of 4 seats (the introduction also says 4 / 6 / 8 seats); a standard stowed size of 428 × 1760 × 2290 mm per group, a 220 mm deck height when deployed, a suggested opening of 1200-1400 mm (total step width per group) and a suggested pit depth of 430-600 mm (box height); 350-450 W main motor power; wireless control from a tablet; and the Avant Haosheng rear-mounted upholstered seat as the recommended seat.
AO Ranking view: This needs coordination with the building works: pit depth, opening size and power must be fixed at design stage. The page does not say which figure is length, width or height, and notes that sizes and drives vary with seat count and seat model, so the figures cannot go straight into construction drawings. The page carries the site-wide reference list (QB/T 2601-2013, EN 13200-4:2006, EN 12727-2016, DIN 4102-1, BS 5852:2006 and others) but no test report number or load and durability figures for this model.
The Avant telescopic stand system in the library (news page) has a 244 mm rise and 1020 mm closed depth and suits large halls; this system stows below the floor and suits multi-purpose rooms that need a fully flat floor. This is a mechanical comparison of page information, not an AO Ranking measurement.
Suitable settings
- Multi-purpose rooms and lecture halls
- Spaces that need a flat floor
Buying checklist
- Fix pit depth, opening and power at design stage
- Confirm seats per group, seat model and drive
- Request safety interlock, anti-trap and power-loss procedures
Peer comparison
The Avant telescopic stand system in the library (news page) has a 244 mm rise and 1020 mm closed depth and suits large halls; this system stows below the floor and suits multi-purpose rooms that need a fully flat floor. This is a mechanical comparison of page information, not an AO Ranking measurement.
Source-scoped parameters
Drive per group
One drive per group of 4 seats
Original scope conditions
Publisher-reported catalogue statement only; not independent certification, orderability, stock or install adequacy.
Seats per unit
4 / 6 / 8 seats
Original scope conditions
Publisher-reported catalogue statement only; not independent certification, orderability, stock or install adequacy.
Stowed size per group
428*1760*2290mm
Original scope conditions
Publisher-reported catalogue statement only; not independent certification, orderability, stock or install adequacy.
Deck height when deployed
220mm
Original scope conditions
Publisher-reported catalogue statement only; not independent certification, orderability, stock or install adequacy.
Suggested opening
1200-1400 mm (total step width per group)
Original scope conditions
Publisher-reported catalogue statement only; not independent certification, orderability, stock or install adequacy.
Suggested pit depth
430-600 mm (box height)
Original scope conditions
Publisher-reported catalogue statement only; not independent certification, orderability, stock or install adequacy.
Main motor power
350W-450W
Original scope conditions
Publisher-reported catalogue statement only; not independent certification, orderability, stock or install adequacy.
Control
Wireless control via a smart screen or tablet
Original scope conditions
Publisher-reported catalogue statement only; not independent certification, orderability, stock or install adequacy.
| Parameter | Original value & unit | Conditions, scope & source |
|---|---|---|
| Drive per group | One drive per group of 4 seats | Original scope conditionsPublisher-reported catalogue statement only; not independent certification, orderability, stock or install adequacy. |
| Seats per unit | 4 / 6 / 8 seats | Original scope conditionsPublisher-reported catalogue statement only; not independent certification, orderability, stock or install adequacy. |
| Stowed size per group | 428*1760*2290mm | Original scope conditionsPublisher-reported catalogue statement only; not independent certification, orderability, stock or install adequacy. |
| Deck height when deployed | 220mm | Original scope conditionsPublisher-reported catalogue statement only; not independent certification, orderability, stock or install adequacy. |
| Suggested opening | 1200-1400 mm (total step width per group) | Original scope conditionsPublisher-reported catalogue statement only; not independent certification, orderability, stock or install adequacy. |
| Suggested pit depth | 430-600 mm (box height) | Original scope conditionsPublisher-reported catalogue statement only; not independent certification, orderability, stock or install adequacy. |
| Main motor power | 350W-450W | Original scope conditionsPublisher-reported catalogue statement only; not independent certification, orderability, stock or install adequacy. |
| Control | Wireless control via a smart screen or tablet | Original scope conditionsPublisher-reported catalogue statement only; not independent certification, orderability, stock or install adequacy. |
Sources & retrieval dates
Documented source dates
- Source acquisition record