Huilang
Huilang HFS sports floodlight (300-800 W)
HFS is the square sports floodlight in the single spec sheet (V01, 13 Oct 2021) attached to the HFS1, HFS2 and HFS3 product pages on the Huilang site, listed for football, basketball and tennis courts, badminton halls and swimming pools. The table gives rated power 300/400/600/800 W with 39,000/52,000/78,000/104,000 lm, efficacy 130 lm/W, CCT 3000/4000/5000/5700 K, CRI >80, IP54, dimensions 330 x 520 x 125 mm (300/400 W) and 658 x 520 x 180 mm (600/800 W), luminaire weight 7 kg and 15 kg, and operating temperature -25 to +40 C; one row reads 50000 with no label (the HFS-T table in the same sheet labels that row average source life in hours). Packaging: cartons 560 x 370 x 180 mm and 560 x 698 x 230 mm, net 7/15 kg, gross 9/17 kg. AO Ranking view: The sheet contradicts itself on voltage: the table gives rated voltage 220 V AC, 50 Hz, while the instructions give 100-305 V, 50/60 Hz, so confirm the supply range in writing before specifying. IP54 is low among lighting products in the library (TPK and Sportsbeams are mostly IP66), which points to indoor or sheltered mounting; ask before exposing it to direct rain. In the same housing and weight, 400 W gives 13,000 lm more than 300 W, and 800 W 26,000 lm more than 600 W, so the higher step in each housing yields more light per fixture, though the maker should explain the thermal margin. Mechanical comparison of page figures, not an AO Ranking measurement.
- Brand / publisher
- Huilang · Suzhou Huilang Lighting Co., Ltd.
- Model
- HFS
- Category
- Sports lighting
- Region / configuration
- Region in original source · 300W/400W
Up to 4 records; compare original sources without recommendations or performance ranks.
Models and configurations retain their source scope. Check specifications against the venue and intended use.
Scope
Identity type: published_catalogue_model; limited to statements on the official product page. No orderable SKU, independent certification, stock or install suitability inferred.
AO Ranking Review
HFS is the square sports floodlight in the single spec sheet (V01, 13 Oct 2021) attached to the HFS1, HFS2 and HFS3 product pages on the Huilang site, listed for football, basketball and tennis courts, badminton halls and swimming pools. The table gives rated power 300/400/600/800 W with 39,000/52,000/78,000/104,000 lm, efficacy 130 lm/W, CCT 3000/4000/5000/5700 K, CRI >80, IP54, dimensions 330 x 520 x 125 mm (300/400 W) and 658 x 520 x 180 mm (600/800 W), luminaire weight 7 kg and 15 kg, and operating temperature -25 to +40 C; one row reads 50000 with no label (the HFS-T table in the same sheet labels that row average source life in hours). Packaging: cartons 560 x 370 x 180 mm and 560 x 698 x 230 mm, net 7/15 kg, gross 9/17 kg.
AO Ranking view: The sheet contradicts itself on voltage: the table gives rated voltage 220 V AC, 50 Hz, while the instructions give 100-305 V, 50/60 Hz, so confirm the supply range in writing before specifying. IP54 is low among lighting products in the library (TPK and Sportsbeams are mostly IP66), which points to indoor or sheltered mounting; ask before exposing it to direct rain. In the same housing and weight, 400 W gives 13,000 lm more than 300 W, and 800 W 26,000 lm more than 600 W, so the higher step in each housing yields more light per fixture, though the maker should explain the thermal margin.
Mechanical comparison of page figures, not an AO Ranking measurement.
Suitable settings
- Sheltered or indoor lighting in basketball, badminton or swimming halls
- Small and medium venues that want a 300-800 W square floodlight
Buying checklist
- Have the maker confirm in writing whether rated voltage is 220 V or 100-305 V
- Ask about water exposure before using IP54 outdoors
- Ask for beam curves and a tested efficacy report
Peer comparison
In the library, Fengshun Qiming FSQM-T: 130-139 lm/W, IP67; Sportsbeams S1000: IP66, 116,000 lm peak. HFS 800 W is 104,000 lm in the table, IP54, 15 kg. Mechanical comparison of page figures, not an AO Ranking measurement.
Source-scoped parameters
Model
HFS系列
Original scope conditions
As listed on the official product page; publisher-reported, no independent test conditions stated
Rated power
300、400、600、800
Original scope conditions
As listed on the official product page; publisher-reported, no independent test conditions stated
Luminous flux
39000、52000、78000、104000
Original scope conditions
As listed on the official product page; publisher-reported, no independent test conditions stated
Luminous efficacy
130
Original scope conditions
As listed on the official product page; publisher-reported, no independent test conditions stated
Rated voltage (parameter table)
220V~,50Hz
Original scope conditions
As printed in the parameter table; the instructions on p.5 of the same sheet give 100-305 V, 50/60 Hz
Rated voltage (instructions)
100-305V,频率50/60Hz
Original scope conditions
As printed in the instructions; the parameter table gives 220 V AC, 50 Hz
Correlated colour temperature
3000、4000、5000、5700
Original scope conditions
As listed on the official product page; publisher-reported, no independent test conditions stated
Colour rendering index
CRI>80
Original scope conditions
As listed on the official product page; publisher-reported, no independent test conditions stated
Ingress protection
IP54
Original scope conditions
As listed on the official product page; publisher-reported, no independent test conditions stated
Dimensions (300/400 W)
330×520×125
Original scope conditions
As listed on the official product page; publisher-reported, no independent test conditions stated
Dimensions (600/800 W)
658×520×180
Original scope conditions
As listed on the official product page; publisher-reported, no independent test conditions stated
Luminaire weight (300/400 W)
7
Original scope conditions
As listed on the official product page; publisher-reported, no independent test conditions stated
Luminaire weight (600/800 W)
15
Original scope conditions
As listed on the official product page; publisher-reported, no independent test conditions stated
Unlabelled row
50000
Original scope conditions
Printed without a label; the HFS-T table in the same sheet labels this row average source life (h)
Operating temperature
-25~+40
Original scope conditions
As listed on the official product page; publisher-reported, no independent test conditions stated
Carton size (300/400 W)
560×370×180
Original scope conditions
As listed on the official product page; publisher-reported, no independent test conditions stated
Carton size (600/800 W)
560×698×230
Original scope conditions
As listed on the official product page; publisher-reported, no independent test conditions stated
Gross weight (300/400 W / 600/800 W)
9 / 17
Original scope conditions
As listed on the official product page; publisher-reported, no independent test conditions stated
| Parameter | Original value & unit | Conditions, scope & source |
|---|---|---|
| Model | HFS系列 | Original scope conditionsAs listed on the official product page; publisher-reported, no independent test conditions stated |
| Rated power | 300、400、600、800 | Original scope conditionsAs listed on the official product page; publisher-reported, no independent test conditions stated |
| Luminous flux | 39000、52000、78000、104000 | Original scope conditionsAs listed on the official product page; publisher-reported, no independent test conditions stated |
| Luminous efficacy | 130 | Original scope conditionsAs listed on the official product page; publisher-reported, no independent test conditions stated |
| Rated voltage (parameter table) | 220V~,50Hz | Original scope conditionsAs printed in the parameter table; the instructions on p.5 of the same sheet give 100-305 V, 50/60 Hz |
| Rated voltage (instructions) | 100-305V,频率50/60Hz | Original scope conditionsAs printed in the instructions; the parameter table gives 220 V AC, 50 Hz |
| Correlated colour temperature | 3000、4000、5000、5700 | Original scope conditionsAs listed on the official product page; publisher-reported, no independent test conditions stated |
| Colour rendering index | CRI>80 | Original scope conditionsAs listed on the official product page; publisher-reported, no independent test conditions stated |
| Ingress protection | IP54 | Original scope conditionsAs listed on the official product page; publisher-reported, no independent test conditions stated |
| Dimensions (300/400 W) | 330×520×125 | Original scope conditionsAs listed on the official product page; publisher-reported, no independent test conditions stated 300W/400W Open source ↗ |
| Dimensions (600/800 W) | 658×520×180 | Original scope conditionsAs listed on the official product page; publisher-reported, no independent test conditions stated 600W/800W Open source ↗ |
| Luminaire weight (300/400 W) | 7 | Original scope conditionsAs listed on the official product page; publisher-reported, no independent test conditions stated 300W/400W Open source ↗ |
| Luminaire weight (600/800 W) | 15 | Original scope conditionsAs listed on the official product page; publisher-reported, no independent test conditions stated 600W/800W Open source ↗ |
| Unlabelled row | 50000 | Original scope conditionsPrinted without a label; the HFS-T table in the same sheet labels this row average source life (h) |
| Operating temperature | -25~+40 | Original scope conditionsAs listed on the official product page; publisher-reported, no independent test conditions stated |
| Carton size (300/400 W) | 560×370×180 | Original scope conditionsAs listed on the official product page; publisher-reported, no independent test conditions stated 300W/400W Open source ↗ |
| Carton size (600/800 W) | 560×698×230 | Original scope conditionsAs listed on the official product page; publisher-reported, no independent test conditions stated 600W/800W Open source ↗ |
| Gross weight (300/400 W / 600/800 W) | 9 / 17 | Original scope conditionsAs listed on the official product page; publisher-reported, no independent test conditions stated |
Sources & retrieval dates
Documented source dates
- Source acquisition record

